// TODO PortDirection treatment here is similar to the one in createPpPortMapping.
// Some code alignment must be considered.
- if (port.getPartnerPort() == null
- || port.getPartnerPort().getCircuitPackName() == null
- || port.getPartnerPort().getPortName() == null) {
+ if (!checkPartnerPortNotNull(port)) {
LOG.warn("Error in the configuration of port {} of {} for {}",
port.getPortName(), circuitPackName, nodeId);
continue;
// TODO PortDirection treatment here is similar to the one in createPpPortMapping.
// Some code alignment must be considered.
- if (port.getPartnerPort() == null
- || port.getPartnerPort().getCircuitPackName() == null
- || port.getPartnerPort().getPortName() == null) {
+ if (!checkPartnerPortNotNull(port)) {
LOG.warn("Error in the configuration of port {} of {} for {}",
port.getPortName(), circuitPackName, nodeId);
continue;
return true;
}
- private boolean checkPartnerPort(String circuitPackName, Ports port1, Ports port2) {
- if (port2.getPartnerPort() == null
- || port2.getPartnerPort().getCircuitPackName() == null
- || port2.getPartnerPort().getPortName() == null
+ private boolean checkPartnerPortNotNull(Ports port) {
+ if (port.getPartnerPort() == null
+ || port.getPartnerPort().getCircuitPackName() == null
+ || port.getPartnerPort().getPortName() == null) {
+ return false;
+ }
+ return true;
+ }
+
+ private boolean checkPartnerPortNoDir(String circuitPackName, Ports port1, Ports port2) {
+ if (!checkPartnerPortNotNull(port2)
|| !port2.getPartnerPort().getCircuitPackName().equals(circuitPackName)
- || !port2.getPartnerPort().getPortName().equals(port1.getPortName())
+ || !port2.getPartnerPort().getPortName().equals(port1.getPortName())) {
+ return false;
+ }
+ return true;
+ }
+
+ private boolean checkPartnerPort(String circuitPackName, Ports port1, Ports port2) {
+ if (!checkPartnerPortNoDir(circuitPackName, port1, port2)
|| ((Direction.Rx.getIntValue() != port1.getPortDirection().getIntValue()
|| Direction.Tx.getIntValue() != port2.getPortDirection().getIntValue())
&&
case Rx:
case Tx:
- if (port.getPartnerPort() == null) {
- LOG.info("{} : port {} on {} is unidirectional but has no partnerPort"
+ if (!checkPartnerPortNotNull(port)) {
+ LOG.info("{} : port {} on {} is unidirectional but has no valid partnerPort"
+ " - cannot assign logicalConnectionPoint.",
nodeId, port.getPortName(), circuitPackName);
continue;
port2.getPortName(), cp2Name, port1.getPortName(), cp1Name);
continue;
}
- // TODO this second checkPartnerPort call has overlap checkings with the first one (Directions)
- if (!checkPartnerPort(cp2Name, port2, port1)) {
+ // Directions checks are the same for cp1 and cp2, no need to check them twice.
+ if (!checkPartnerPortNoDir(cp2Name, port2, port1)) {
LOG.error("port {} on {} is not a correct partner port of {} on {}",
port1.getPortName(), cp1Name, port2.getPortName(), cp2Name);
continue;