Honeynode Enhancements
[transportpce.git] / tests / ordmodels_2_1 / org-openroadm-alarm@2016-10-14.yang
diff --git a/tests/ordmodels_2_1/org-openroadm-alarm@2016-10-14.yang b/tests/ordmodels_2_1/org-openroadm-alarm@2016-10-14.yang
deleted file mode 100644 (file)
index 5ed8792..0000000
+++ /dev/null
@@ -1,127 +0,0 @@
-module org-openroadm-alarm {
-  namespace "http://org/openroadm/alarm";
-  prefix org-openroadm-alarm;
-
-  import ietf-yang-types {
-    prefix yang;
-  }
-  import org-openroadm-common-types {
-    prefix org-openroadm-common-types;
-  }
-  import org-openroadm-resource {
-    prefix org-openroadm-resource;
-  }
-  import org-openroadm-probable-cause {
-    prefix org-openroadm-probable-cause;
-  }
-
-  organization "Open ROADM MSA";
-  contact
-    "OpenROADM.org";
-  description
-    "YANG definitions of an alarm.
-
-     Copyright of the Members of the Open ROADM MSA Agreement dated (c) 2016,
-     AT&T Intellectual Property.  All other rights reserved.
-
-     Redistribution and use in source and binary forms, with or without modification,
-     are permitted provided that the following conditions are met:
-
-     * Redistributions of source code must retain the above copyright notice, this
-       list of conditions and the following disclaimer.
-     * Redistributions in binary form must reproduce the above copyright notice,
-       this list of conditions and the following disclaimer in the documentation and/or
-       other materials provided with the distribution.
-     * Neither the Members of the Open ROADM MSA Agreement nor the names of its
-       contributors may be used to endorse or promote products derived from this software
-       without specific prior written permission.
-
-     THIS SOFTWARE IS PROVIDED BY THE MEMBERS OF THE OPEN ROADM MSA  AGREEMENT ''AS IS''
-     AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
-     WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED.
-     IN NO EVENT THE MEMBERS OF THE OPEN ROADM MSA  AGREEMENT BE LIABLE FOR ANY DIRECT,
-     INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
-     NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;  LOSS OF USE, DATA,
-     OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY,
-     WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
-     ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
-     POSSIBILITY OF SUCH DAMAGE.";
-
-  revision 2016-10-14 {
-    description
-      "Version 1.2";
-  }
-
-  grouping alarm {
-    leaf id {
-      description
-        "Uniquely id for this alarm, within the given management domain";
-      type string;
-      mandatory true;
-    }
-    container resource {
-      description
-        "Resource under alarm";
-      uses org-openroadm-resource:resource;
-    }
-    container probableCause {
-      description
-        "Probable cause of alarm";
-      uses org-openroadm-probable-cause:probable-cause;
-    }
-    leaf type {
-      description
-        "Type of alarm. Based on X.733 event Type.";
-      mandatory false;
-      type enumeration {
-        enum "communication" {
-          value 1;
-        }
-        enum "qualityOfService" {
-          value 2;
-        }
-        enum "processingError" {
-          value 3;
-        }
-        enum "equipment" {
-          value 4;
-        }
-        enum "environmental" {
-          value 5;
-        }
-      }
-    }
-    leaf raiseTime {
-      description
-        "Time alarm was raised";
-      type yang:date-and-time;
-      mandatory true;
-    }
-    leaf severity {
-      description
-        "Severity of alarm. Based on X.733 perceived severity.";
-      mandatory true;
-      type org-openroadm-common-types:severity;
-    }
-    leaf circuit-id {
-      description
-        "Circuit-id for alarm correlation.";
-      type string;
-    }
-  }
-
-  container active-alarm-list {
-    description
-      "List of currently active alarms. An alarm is removed from this table when the state transitions to clear.";
-    list activeAlarms {
-      key "id";
-      uses alarm;
-    }
-    config false;
-  }
-  notification alarm-notification {
-    description
-      "Notification sent on initial alarm creation, as well as any time the alarm changes state, including clear";
-    uses alarm;
-  }
-}