Fix odu-switching-pool configuration for OTN mpdr
[transportpce.git] / tests / sample_configs / openroadm / 2.2.1 / oper-SPDRC.xml
index 3b3f990f4d542136508afc79da326e7409c12c25..9efe009afaf1650d6c70a804c2f68e5c7cecd036 100644 (file)
@@ -3,7 +3,7 @@
   <netconf xmlns="urn:ietf:params:xml:ns:netmod:notification">
     <streams>
       <stream>
-        <name>OPENROADM</name>
+        <name>NETCONF</name>
       </stream>
     </streams>
   </netconf>
         <slot-name>CP3-S10</slot-name>
         <label>CP3S10</label>
       </cp-slots>
-         <cp-slots>
+      <cp-slots>
         <slot-name>CP3-S11</slot-name>
         <label>CP3S11</label>
       </cp-slots>
         <slot-name>CP3-S20</slot-name>
         <label>CP3S20</label>
       </cp-slots>
-         <cp-slots>
+      <cp-slots>
         <slot-name>CP3-S21</slot-name>
         <label>CP3S21</label>
       </cp-slots>
         <slot-name>CP3-S30</slot-name>
         <label>CP3S30</label>
       </cp-slots>
-         <cp-slots>
+      <cp-slots>
         <slot-name>CP3-S31</slot-name>
         <label>CP3S31</label>
       </cp-slots>
         <slot-name>CP3-S40</slot-name>
         <label>CP3S40</label>
       </cp-slots>
-         <cp-slots>
+      <cp-slots>
         <slot-name>CP3-S41</slot-name>
         <label>CP3S41</label>
       </cp-slots>
         <slot-name>CP3-S50</slot-name>
         <label>CP3S50</label>
       </cp-slots>
-         <cp-slots>
+      <cp-slots>
         <slot-name>CP3-S51</slot-name>
         <label>CP3S51</label>
       </cp-slots>
         <slot-name>CP3-S60</slot-name>
         <label>CP3S60</label>
       </cp-slots>
-         <cp-slots>
+      <cp-slots>
         <slot-name>CP3-S61</slot-name>
         <label>CP3S61</label>
       </cp-slots>
         <slot-name>CP3-S70</slot-name>
         <label>CP3S70</label>
       </cp-slots>
-         <cp-slots>
+      <cp-slots>
         <slot-name>CP3-S71</slot-name>
         <label>CP3S71</label>
       </cp-slots>
         <eqpt-srg-id>6</eqpt-srg-id>
       </xpdr-port>
     </xponder>
-       <xponder>
+    <xponder>
       <xpdr-number>3</xpdr-number>
       <xpdr-type>mpdr</xpdr-type>
       <xpdr-port>
     </xponder>
     <odu-switching-pools>
       <switching-pool-number>1</switching-pool-number>
-      <switching-pool-type xmlns:org-openroadm-switching-pool-types="http://org/openroadm/switching-pool-types">non-blocking</switching-pool-type>
+      <switching-pool-type xmlns:org-openroadm-switching-pool-types="http://org/openroadm/switching-pool-types">blocking</switching-pool-type>
       <non-blocking-list>
         <nbl-number>1</nbl-number>
         <interconnect-bandwidth-unit>1000000000</interconnect-bandwidth-unit>
         </port-list>
       </non-blocking-list>
     </odu-switching-pools>
-       <odu-switching-pools>
+    <odu-switching-pools>
       <switching-pool-number>3</switching-pool-number>
-      <switching-pool-type xmlns:org-openroadm-switching-pool-types="http://org/openroadm/switching-pool-types">non-blocking</switching-pool-type>
+      <switching-pool-type xmlns:org-openroadm-switching-pool-types="http://org/openroadm/switching-pool-types">blocking</switching-pool-type>
       <non-blocking-list>
         <nbl-number>1</nbl-number>
         <interconnect-bandwidth-unit>1000000000</interconnect-bandwidth-unit>
           <slot-name>CP3-S0</slot-name>
         </pluggable-optics-holder-list>
       </non-blocking-list>
-         <non-blocking-list>
+      <non-blocking-list>
         <nbl-number>11</nbl-number>
         <interconnect-bandwidth-unit>1000000000</interconnect-bandwidth-unit>
         <interconnect-bandwidth>0</interconnect-bandwidth>
           <slot-name>CP3-S0</slot-name>
         </pluggable-optics-holder-list>
       </non-blocking-list>
-         <non-blocking-list>
+      <non-blocking-list>
         <nbl-number>21</nbl-number>
         <interconnect-bandwidth-unit>1000000000</interconnect-bandwidth-unit>
         <interconnect-bandwidth>0</interconnect-bandwidth>
           <slot-name>CP3-S0</slot-name>
         </pluggable-optics-holder-list>
       </non-blocking-list>
-         <non-blocking-list>
+      <non-blocking-list>
         <nbl-number>31</nbl-number>
         <interconnect-bandwidth-unit>1000000000</interconnect-bandwidth-unit>
         <interconnect-bandwidth>0</interconnect-bandwidth>
           <slot-name>CP3-S0</slot-name>
         </pluggable-optics-holder-list>
       </non-blocking-list>
-         <non-blocking-list>
+      <non-blocking-list>
         <nbl-number>41</nbl-number>
         <interconnect-bandwidth-unit>1000000000</interconnect-bandwidth-unit>
         <interconnect-bandwidth>0</interconnect-bandwidth>
           <slot-name>CP3-S0</slot-name>
         </pluggable-optics-holder-list>
       </non-blocking-list>
-         <non-blocking-list>
+      <non-blocking-list>
         <nbl-number>51</nbl-number>
         <interconnect-bandwidth-unit>1000000000</interconnect-bandwidth-unit>
         <interconnect-bandwidth>0</interconnect-bandwidth>
           <slot-name>CP3-S0</slot-name>
         </pluggable-optics-holder-list>
       </non-blocking-list>
-         <non-blocking-list>
+      <non-blocking-list>
         <nbl-number>61</nbl-number>
         <interconnect-bandwidth-unit>1000000000</interconnect-bandwidth-unit>
         <interconnect-bandwidth>0</interconnect-bandwidth>
           <slot-name>CP3-S0</slot-name>
         </pluggable-optics-holder-list>
       </non-blocking-list>
-         <non-blocking-list>
+      <non-blocking-list>
         <nbl-number>71</nbl-number>
         <interconnect-bandwidth-unit>1000000000</interconnect-bandwidth-unit>
         <interconnect-bandwidth>0</interconnect-bandwidth>