BUG-2637: migration final - cleanup
[controller.git] / opendaylight / md-sal / statistics-manager / src / main / java / org / opendaylight / controller / md / statistics / manager / StatPermCollector.java
diff --git a/opendaylight/md-sal/statistics-manager/src/main/java/org/opendaylight/controller/md/statistics/manager/StatPermCollector.java b/opendaylight/md-sal/statistics-manager/src/main/java/org/opendaylight/controller/md/statistics/manager/StatPermCollector.java
deleted file mode 100644 (file)
index 94d6dfa..0000000
+++ /dev/null
@@ -1,126 +0,0 @@
-/**
- * Copyright (c) 2014 Cisco Systems, Inc. and others.  All rights reserved.
- *
- * This program and the accompanying materials are made available under the
- * terms of the Eclipse Public License v1.0 which accompanies this distribution,
- * and is available at http://www.eclipse.org/legal/epl-v10.html
- */
-
-package org.opendaylight.controller.md.statistics.manager;
-
-import java.util.List;
-
-import org.opendaylight.yang.gen.v1.urn.opendaylight.flow.transaction.rev131103.TransactionId;
-import org.opendaylight.yang.gen.v1.urn.opendaylight.inventory.rev130819.nodes.Node;
-import org.opendaylight.yangtools.yang.binding.InstanceIdentifier;
-
-/**
- * statistics-manager
- * org.opendaylight.controller.md.statistics.manager
- *
- * StatPermCollector
- * Class implement {@link Runnable} and inside is running statistic collecting
- * process DataObject statistics by DataObject statistics for every {@link org.opendaylight.yang.gen.v1.urn.opendaylight.flow.inventory.rev130819.FlowCapableNode}.
- * Every statistics wait to finish previous statistics. Only if all statistics finish,
- * next {@link org.opendaylight.yang.gen.v1.urn.opendaylight.flow.inventory.rev130819.FlowCapableNode}
- * Statistics should be collecting. We are able to set minimal time for start next round cross all Network,
- * but all depends on network possibility.
- *
- * @author <a href="mailto:vdemcak@cisco.com">Vaclav Demcak</a>
- *
- * Created: Aug 28, 2014
- */
-public interface StatPermCollector extends Runnable, AutoCloseable {
-
-    /**
-     * StatCapType
-     * Enum class refers ofp_statistics capabilities fields from OF Switch
-     * capabilities specification which have to come as a post HandShake
-     * information from OF Switch and Inventory Manager adds all to the
-     * Operational/DS.
-     * If the capabilities are not add (for any reason) NodeRegistrator
-     * adds all StatCapTypes for the {@link Node}.
-     */
-    public enum StatCapabTypes {
-        /**
-         * OFPC_FLOW_STATS
-         */
-        FLOW_STATS,
-        /**
-         * OFPC_TABLE_STATS
-         */
-        TABLE_STATS,
-        /**
-         * OFPC_PORT_STATS
-         */
-        PORT_STATS,
-        /**
-         * OFPC_GROUP_STATS
-         */
-        GROUP_STATS,
-        /**
-         * OFPC_QUEUE_STATS
-         */
-        QUEUE_STATS,
-        /**
-         * Meter statistics has no support from OF Switch capabilities
-         * so we have to try get statistics for it and wait for response
-         * Error or response package with results.
-         */
-        METER_STATS
-    }
-
-    /**
-     * Add new connected node for permanent statistics collecting process
-     *
-     * @param flowNode
-     * @param statTypes
-     * @param nrOfSwitchTables
-     * @return true/false if the {@link Node} added successful
-     */
-    boolean connectedNodeRegistration(InstanceIdentifier<Node> nodeIdent,
-            List<StatCapabTypes> statTypes, Short nrOfSwitchTables);
-
-    /**
-     * All disconnected Nodes need be removed from stat list Nodes
-     *
-     * @param flowNode
-     * @return true/false if the {@link Node} removed successful
-     */
-    boolean disconnectedNodeUnregistration(InstanceIdentifier<Node> nodeIdent);
-
-    /**
-     * Method add new feature {@link StatCapabTypes} to Node identified by
-     * nodeIdent -> InstanceIdentifier<Node>
-     *
-     * @param flowNode
-     * @return true/false if the {@link StatCapabTypes} add successful
-     */
-    boolean registerAdditionalNodeFeature(InstanceIdentifier<Node> nodeIdent, StatCapabTypes statCapab);
-
-    /**
-     * Method return true only and only if {@link StatPermCollector} contain
-     * valid node registration in its internal {@link Node} map.
-     * Otherwise return false.
-     *
-     * @param flowNode
-     * @return
-     */
-    boolean isProvidedFlowNodeActive(InstanceIdentifier<Node> nodeIdent);
-
-    /**
-     * Object notification for continue statistics collecting process.
-     * It is call from collecting allStatistics methods as a future result for
-     * Operational/DS statistic store call (does not matter in the outcome).
-     */
-    void collectNextStatistics(TransactionId xid);
-
-    /**
-     * Method returns true if collector has registered some active nodes
-     * otherwise return false.
-     *
-     * @return
-     */
-    boolean hasActiveNodes();
-}
-