2 Documentation Test suite for Hbase DataStore FlowMeter Stats Verification
3 Suite Setup Run Keywords Start TSDR suite with CPqD Switch Configuration of FlowMeter on Switch
4 Suite Teardown Stop Tsdr Suite
8 Library ../../../libraries/Common.py
9 Resource ../../../libraries/KarafKeywords.robot
10 Resource ../../../libraries/TsdrUtils.robot
11 Variables ../../../variables/Variables.py
14 @{FLOWMETER_METRICS} ByteInCount PacketInCount FlowCount
15 ${TSDR_FLOWMETERSTATS} tsdr:list FlowMeterStats
16 @{FLOWMETER_HEADER} MetricName MetricValue MetricCategory MetricDetails
19 Verify the FlowMeter Stats attributes exist thru Karaf console
20 [Documentation] Verify the FlowMeterStats attributes exist on Karaf Console
21 Wait Until Keyword Succeeds 180s 1s Verify the Metric is Collected? ${TSDR_FLOWMETERSTATS} ByteInCount
22 ${output}= Issue Command On Karaf Console ${TSDR_FLOWMETERSTATS} ${CONTROLLER} ${KARAF_SHELL_PORT} 30
23 : FOR ${list} IN @{FLOWMETER_METRICS}
24 \ Should Contain ${output} ${list}
26 Verification of FlowMeterStats-ByteInCount on Karaf Console
27 [Documentation] Verify the FlowMeterStats has been updated thru tsdr:list command on karaf console
28 ${tsdr_cmd}= Concatenate the String ${TSDR_FLOWMETERSTATS} | grep ByteInCount | head
29 ${output}= Issue Command On Karaf Console ${tsdr_cmd} ${CONTROLLER} ${KARAF_SHELL_PORT} 90
30 Should Contain ${output} ByteInCount
31 Should Contain ${output} FlowMeterStats
32 Should not Contain ${output} null
33 : FOR ${list} IN @{FLOWMETER_HEADER}
34 \ Should Contain ${output} ${list}
36 Verification of FlowMeterStats-ByteInCount on HBase Client
37 [Documentation] Verify the FlowMeterStats has been updated on HBase Datastore
38 ${query}= Generate HBase Query MeterMetrics ByteInCount_openflow:1
39 ${out}= Query the Data from HBaseClient ${query}
40 Should Match Regexp ${out} (?mui)ByteInCount
42 Verification of FlowMeterStats-PacketInCount on HBase Client
43 [Documentation] Verify the FlowMeterStats has been updated on HBase Datastore
44 ${query}= Generate HBase Query MeterMetrics PacketInCount_openflow:1
45 ${out}= Query the Data from HBaseClient ${query}
46 Should Match Regexp ${out} (?mui)PacketInCount
48 Verification of FlowMeterStats-FlowCount on HBase Client
49 [Documentation] Verify the FlowMeterStats has been updated on HBase Datastore
50 ${query}= Generate HBase Query MeterMetrics FlowCount_openflow:1
51 ${out}= Query the Data from HBaseClient ${query}
52 Should Match Regexp ${out} (?mui)FlowCount
54 Uninstall all TSDR HBase Feature
55 [Documentation] UnInstall all TSDR HBase Features
56 Uninstall a Feature odl-tsdr-hbase-persistence odl-hbaseclient odl-tsdr-core odl-tsdr-hbase
57 Verify Feature Is Not Installed odl-tsdr-hbase-persistence
58 Verify Feature Is Not Installed odl-hbaseclient
59 Verify Feature Is Not Installed odl-tsdr-core
60 Verify Feature Is Not Installed odl-tsdr-hbase
62 Verification TSDR Command shouldnot exist in help
63 [Documentation] Verify the TSDR List command on help
64 ${output}= Issue Command On Karaf Console tsdr\t ${CONTROLLER} ${KARAF_SHELL_PORT}
65 Should not Contain ${output} tsdr:list
68 Start TSDR suite with CPqD Switch
71 Configuration of FlowMeter on Switch
72 [Documentation] FlowMeter configuration on CPqD
73 Run Command On Remote System ${MININET} sudo dpctl unix:/tmp/s1 meter-mod cmd=add,flags=1,meter=1 drop:rate=100
74 Run Command On Remote System ${MININET} sudo dpctl unix:/tmp/s1 flow-mod table=0,cmd=add in_port=1 meter:1 apply:output=2
75 Run Command On Remote System ${MININET} sudo dpctl unix:/tmp/s1 ping 10