<data xmlns="urn:ietf:params:xml:ns:netconf:base:1.0">
<network xmlns="http://org/opendaylight/transportpce/portmapping">
<nodes>
- <node-id>XPDR-C1</node-id>
+ <node-id>XPDR-A1</node-id>
<node-info>
- <node-type>xpdr</node-type>
- <node-ip-address>1.2.3.4</node-ip-address>
- <node-clli>NodeC</node-clli>
<openroadm-version>2.2.1</openroadm-version>
- <node-vendor>vendorA</node-vendor>
<node-model>model2</node-model>
+ <node-clli>NodeA</node-clli>
+ <node-type>xpdr</node-type>
+ <node-vendor>vendorA</node-vendor>
+ <node-ip-address>1.2.3.4</node-ip-address>
</node-info>
<mapping>
- <logical-connection-point>XPDR1-NETWORK1</logical-connection-point>
- <supporting-circuit-pack-name>1/0/1-PLUG-NET</supporting-circuit-pack-name>
+ <logical-connection-point>XPDR1-NETWORK2</logical-connection-point>
<port-qual>xpdr-network</port-qual>
- <associated-lcp>XPDR1-CLIENT1</associated-lcp>
- <port-direction>bidirectional</port-direction>
+ <connection-map-lcp>XPDR1-CLIENT2</connection-map-lcp>
+ <supporting-circuit-pack-name>1/0/2-PLUG-NET</supporting-circuit-pack-name>
<supporting-port>1</supporting-port>
+ <supported-interface-capability xmlns:x="http://org/openroadm/port/types">x:if-OCH</supported-interface-capability>
+ <port-direction>bidirectional</port-direction>
</mapping>
<mapping>
- <logical-connection-point>XPDR1-NETWORK2</logical-connection-point>
- <supporting-circuit-pack-name>1/0/2-PLUG-NET</supporting-circuit-pack-name>
+ <logical-connection-point>XPDR1-NETWORK1</logical-connection-point>
<port-qual>xpdr-network</port-qual>
- <associated-lcp>XPDR1-CLIENT2</associated-lcp>
- <port-direction>bidirectional</port-direction>
+ <connection-map-lcp>XPDR1-CLIENT1</connection-map-lcp>
+ <supporting-circuit-pack-name>1/0/1-PLUG-NET</supporting-circuit-pack-name>
<supporting-port>1</supporting-port>
+ <supported-interface-capability xmlns:x="http://org/openroadm/port/types">x:if-OCH</supported-interface-capability>
+ <port-direction>bidirectional</port-direction>
</mapping>
<mapping>
<logical-connection-point>XPDR1-CLIENT1</logical-connection-point>
- <supporting-circuit-pack-name>1/0/1-PLUG-CLIENT</supporting-circuit-pack-name>
<port-qual>xpdr-client</port-qual>
- <associated-lcp>XPDR1-NETWORK1</associated-lcp>
- <port-direction>bidirectional</port-direction>
+ <connection-map-lcp>XPDR1-NETWORK1</connection-map-lcp>
+ <supporting-circuit-pack-name>1/0/1-PLUG-CLIENT</supporting-circuit-pack-name>
<supporting-port>C1</supporting-port>
+ <supported-interface-capability xmlns:x="http://org/openroadm/port/types">x:if-100GE</supported-interface-capability>
+ <port-direction>bidirectional</port-direction>
</mapping>
<mapping>
<logical-connection-point>XPDR1-CLIENT2</logical-connection-point>
- <supporting-circuit-pack-name>1/0/2-PLUG-CLIENT</supporting-circuit-pack-name>
<port-qual>xpdr-client</port-qual>
- <associated-lcp>XPDR1-NETWORK2</associated-lcp>
- <port-direction>bidirectional</port-direction>
+ <connection-map-lcp>XPDR1-NETWORK2</connection-map-lcp>
+ <supporting-circuit-pack-name>1/0/2-PLUG-CLIENT</supporting-circuit-pack-name>
<supporting-port>C1</supporting-port>
+ <supported-interface-capability xmlns:x="http://org/openroadm/port/types">x:if-100GE</supported-interface-capability>
+ <port-direction>bidirectional</port-direction>
</mapping>
</nodes>
<nodes>
- <node-id>ROADM-C1</node-id>
+ <node-id>ROADM-A1</node-id>
<node-info>
- <node-type>rdm</node-type>
- <node-ip-address>127.0.0.11</node-ip-address>
- <node-clli>NodeC</node-clli>
<openroadm-version>2.2.1</openroadm-version>
- <node-vendor>vendorA</node-vendor>
<node-model>model2</node-model>
+ <node-clli>NodeA</node-clli>
+ <node-type>rdm</node-type>
+ <node-vendor>vendorA</node-vendor>
+ <node-ip-address>127.0.0.11</node-ip-address>
</node-info>
<cp-to-degree>
<circuit-pack-name>2/0</circuit-pack-name>
<interface-name>1GE-interface-2</interface-name>
</cp-to-degree>
<mapping>
- <logical-connection-point>SRG1-PP1-TXRX</logical-connection-point>
- <supporting-circuit-pack-name>3/0</supporting-circuit-pack-name>
- <port-direction>bidirectional</port-direction>
+ <logical-connection-point>SRG3-PP1-TXRX</logical-connection-point>
+ <supporting-circuit-pack-name>5/0</supporting-circuit-pack-name>
<supporting-port>C1</supporting-port>
- </mapping>
- <mapping>
- <logical-connection-point>DEG1-TTP-TXRX</logical-connection-point>
- <supporting-oms>OMS-DEG1-TTP-TXRX</supporting-oms>
- <supporting-circuit-pack-name>1/0</supporting-circuit-pack-name>
- <supporting-ots>OTS-DEG1-TTP-TXRX</supporting-ots>
<port-direction>bidirectional</port-direction>
- <supporting-port>L1</supporting-port>
</mapping>
<mapping>
<logical-connection-point>SRG1-PP2-TXRX</logical-connection-point>
<supporting-circuit-pack-name>3/0</supporting-circuit-pack-name>
- <port-direction>bidirectional</port-direction>
<supporting-port>C2</supporting-port>
+ <port-direction>bidirectional</port-direction>
</mapping>
<mapping>
- <logical-connection-point>SRG1-PP3-TXRX</logical-connection-point>
+ <logical-connection-point>SRG3-PP4-TXRX</logical-connection-point>
+ <supporting-circuit-pack-name>5/0</supporting-circuit-pack-name>
+ <supporting-port>C4</supporting-port>
+ <port-direction>bidirectional</port-direction>
+ </mapping>
+ <mapping>
+ <logical-connection-point>SRG1-PP4-TXRX</logical-connection-point>
<supporting-circuit-pack-name>3/0</supporting-circuit-pack-name>
+ <supporting-port>C4</supporting-port>
<port-direction>bidirectional</port-direction>
+ </mapping>
+ <mapping>
+ <logical-connection-point>SRG3-PP3-TXRX</logical-connection-point>
+ <supporting-circuit-pack-name>5/0</supporting-circuit-pack-name>
<supporting-port>C3</supporting-port>
+ <port-direction>bidirectional</port-direction>
</mapping>
<mapping>
<logical-connection-point>DEG2-TTP-TXRX</logical-connection-point>
+ <supporting-ots>OTS-DEG2-TTP-TXRX</supporting-ots>
<supporting-circuit-pack-name>2/0</supporting-circuit-pack-name>
+ <supporting-oms>OMS-DEG2-TTP-TXRX</supporting-oms>
+ <supporting-port>L1</supporting-port>
+ <port-direction>bidirectional</port-direction>
+ </mapping>
+ <mapping>
+ <logical-connection-point>SRG1-PP3-TXRX</logical-connection-point>
+ <supporting-circuit-pack-name>3/0</supporting-circuit-pack-name>
+ <supporting-port>C3</supporting-port>
<port-direction>bidirectional</port-direction>
+ </mapping>
+ <mapping>
+ <logical-connection-point>SRG3-PP2-TXRX</logical-connection-point>
+ <supporting-circuit-pack-name>5/0</supporting-circuit-pack-name>
+ <supporting-port>C2</supporting-port>
+ <port-direction>bidirectional</port-direction>
+ </mapping>
+ <mapping>
+ <logical-connection-point>DEG1-TTP-TXRX</logical-connection-point>
+ <supporting-circuit-pack-name>1/0</supporting-circuit-pack-name>
<supporting-port>L1</supporting-port>
+ <port-direction>bidirectional</port-direction>
</mapping>
<mapping>
- <logical-connection-point>SRG1-PP4-TXRX</logical-connection-point>
+ <logical-connection-point>SRG1-PP1-TXRX</logical-connection-point>
<supporting-circuit-pack-name>3/0</supporting-circuit-pack-name>
+ <supporting-port>C1</supporting-port>
<port-direction>bidirectional</port-direction>
- <supporting-port>C4</supporting-port>
</mapping>
</nodes>
<nodes>
- <node-id>XPDR-A1</node-id>
+ <node-id>XPDR-C1</node-id>
<node-info>
- <node-type>xpdr</node-type>
- <node-ip-address>1.2.3.4</node-ip-address>
- <node-clli>NodeA</node-clli>
<openroadm-version>2.2.1</openroadm-version>
- <node-vendor>vendorA</node-vendor>
<node-model>model2</node-model>
+ <node-clli>NodeC</node-clli>
+ <node-type>xpdr</node-type>
+ <node-vendor>vendorA</node-vendor>
+ <node-ip-address>1.2.3.4</node-ip-address>
</node-info>
<mapping>
- <logical-connection-point>XPDR1-NETWORK1</logical-connection-point>
- <supporting-circuit-pack-name>1/0/1-PLUG-NET</supporting-circuit-pack-name>
+ <logical-connection-point>XPDR1-NETWORK2</logical-connection-point>
<port-qual>xpdr-network</port-qual>
- <associated-lcp>XPDR1-CLIENT1</associated-lcp>
- <port-direction>bidirectional</port-direction>
+ <connection-map-lcp>XPDR1-CLIENT2</connection-map-lcp>
+ <supporting-circuit-pack-name>1/0/2-PLUG-NET</supporting-circuit-pack-name>
<supporting-port>1</supporting-port>
+ <supported-interface-capability xmlns:x="http://org/openroadm/port/types">x:if-OCH</supported-interface-capability>
+ <port-direction>bidirectional</port-direction>
</mapping>
<mapping>
- <logical-connection-point>XPDR1-NETWORK2</logical-connection-point>
- <supporting-circuit-pack-name>1/0/2-PLUG-NET</supporting-circuit-pack-name>
+ <logical-connection-point>XPDR1-NETWORK1</logical-connection-point>
<port-qual>xpdr-network</port-qual>
- <associated-lcp>XPDR1-CLIENT2</associated-lcp>
- <port-direction>bidirectional</port-direction>
+ <connection-map-lcp>XPDR1-CLIENT1</connection-map-lcp>
+ <supporting-circuit-pack-name>1/0/1-PLUG-NET</supporting-circuit-pack-name>
<supporting-port>1</supporting-port>
+ <supported-interface-capability xmlns:x="http://org/openroadm/port/types">x:if-OCH</supported-interface-capability>
+ <port-direction>bidirectional</port-direction>
</mapping>
<mapping>
<logical-connection-point>XPDR1-CLIENT1</logical-connection-point>
- <supporting-circuit-pack-name>1/0/1-PLUG-CLIENT</supporting-circuit-pack-name>
<port-qual>xpdr-client</port-qual>
- <associated-lcp>XPDR1-NETWORK1</associated-lcp>
- <port-direction>bidirectional</port-direction>
+ <connection-map-lcp>XPDR1-NETWORK1</connection-map-lcp>
+ <supporting-circuit-pack-name>1/0/1-PLUG-CLIENT</supporting-circuit-pack-name>
<supporting-port>C1</supporting-port>
+ <supported-interface-capability xmlns:x="http://org/openroadm/port/types">x:if-100GE</supported-interface-capability>
+ <port-direction>bidirectional</port-direction>
</mapping>
<mapping>
<logical-connection-point>XPDR1-CLIENT2</logical-connection-point>
- <supporting-circuit-pack-name>1/0/2-PLUG-CLIENT</supporting-circuit-pack-name>
<port-qual>xpdr-client</port-qual>
- <associated-lcp>XPDR1-NETWORK2</associated-lcp>
- <port-direction>bidirectional</port-direction>
+ <connection-map-lcp>XPDR1-NETWORK2</connection-map-lcp>
+ <supporting-circuit-pack-name>1/0/2-PLUG-CLIENT</supporting-circuit-pack-name>
<supporting-port>C1</supporting-port>
+ <supported-interface-capability xmlns:x="http://org/openroadm/port/types">x:if-100GE</supported-interface-capability>
+ <port-direction>bidirectional</port-direction>
</mapping>
</nodes>
<nodes>
- <node-id>ROADM-A1</node-id>
+ <node-id>ROADM-C1</node-id>
<node-info>
- <node-type>rdm</node-type>
- <node-ip-address>127.0.0.11</node-ip-address>
- <node-clli>NodeA</node-clli>
<openroadm-version>2.2.1</openroadm-version>
- <node-vendor>vendorA</node-vendor>
<node-model>model2</node-model>
+ <node-clli>NodeC</node-clli>
+ <node-type>rdm</node-type>
+ <node-vendor>vendorA</node-vendor>
+ <node-ip-address>127.0.0.11</node-ip-address>
</node-info>
<cp-to-degree>
<circuit-pack-name>2/0</circuit-pack-name>
<interface-name>1GE-interface-2</interface-name>
</cp-to-degree>
<mapping>
- <logical-connection-point>SRG1-PP1-TXRX</logical-connection-point>
+ <logical-connection-point>SRG1-PP2-TXRX</logical-connection-point>
<supporting-circuit-pack-name>3/0</supporting-circuit-pack-name>
- <port-direction>bidirectional</port-direction>
- <supporting-port>C1</supporting-port>
- </mapping>
- <mapping>
- <logical-connection-point>SRG3-PP3-TXRX</logical-connection-point>
- <supporting-circuit-pack-name>5/0</supporting-circuit-pack-name>
- <port-direction>bidirectional</port-direction>
- <supporting-port>C3</supporting-port>
- </mapping>
- <mapping>
- <logical-connection-point>DEG1-TTP-TXRX</logical-connection-point>
- <supporting-circuit-pack-name>1/0</supporting-circuit-pack-name>
- <port-direction>bidirectional</port-direction>
- <supporting-port>L1</supporting-port>
- </mapping>
- <mapping>
- <logical-connection-point>SRG3-PP2-TXRX</logical-connection-point>
- <supporting-circuit-pack-name>5/0</supporting-circuit-pack-name>
- <port-direction>bidirectional</port-direction>
<supporting-port>C2</supporting-port>
- </mapping>
- <mapping>
- <logical-connection-point>SRG3-PP1-TXRX</logical-connection-point>
- <supporting-circuit-pack-name>5/0</supporting-circuit-pack-name>
<port-direction>bidirectional</port-direction>
- <supporting-port>C1</supporting-port>
</mapping>
<mapping>
- <logical-connection-point>SRG1-PP2-TXRX</logical-connection-point>
+ <logical-connection-point>SRG1-PP4-TXRX</logical-connection-point>
<supporting-circuit-pack-name>3/0</supporting-circuit-pack-name>
+ <supporting-port>C4</supporting-port>
<port-direction>bidirectional</port-direction>
- <supporting-port>C2</supporting-port>
</mapping>
<mapping>
- <logical-connection-point>SRG3-PP4-TXRX</logical-connection-point>
- <supporting-circuit-pack-name>5/0</supporting-circuit-pack-name>
+ <logical-connection-point>DEG2-TTP-TXRX</logical-connection-point>
+ <supporting-circuit-pack-name>2/0</supporting-circuit-pack-name>
+ <supporting-port>L1</supporting-port>
<port-direction>bidirectional</port-direction>
- <supporting-port>C4</supporting-port>
</mapping>
<mapping>
<logical-connection-point>SRG1-PP3-TXRX</logical-connection-point>
<supporting-circuit-pack-name>3/0</supporting-circuit-pack-name>
- <port-direction>bidirectional</port-direction>
<supporting-port>C3</supporting-port>
+ <port-direction>bidirectional</port-direction>
</mapping>
<mapping>
- <logical-connection-point>DEG2-TTP-TXRX</logical-connection-point>
- <supporting-oms>OMS-DEG2-TTP-TXRX</supporting-oms>
- <supporting-circuit-pack-name>2/0</supporting-circuit-pack-name>
- <supporting-ots>OTS-DEG2-TTP-TXRX</supporting-ots>
- <port-direction>bidirectional</port-direction>
+ <logical-connection-point>DEG1-TTP-TXRX</logical-connection-point>
+ <supporting-ots>OTS-DEG1-TTP-TXRX</supporting-ots>
+ <supporting-circuit-pack-name>1/0</supporting-circuit-pack-name>
+ <supporting-oms>OMS-DEG1-TTP-TXRX</supporting-oms>
<supporting-port>L1</supporting-port>
+ <port-direction>bidirectional</port-direction>
</mapping>
<mapping>
- <logical-connection-point>SRG1-PP4-TXRX</logical-connection-point>
+ <logical-connection-point>SRG1-PP1-TXRX</logical-connection-point>
<supporting-circuit-pack-name>3/0</supporting-circuit-pack-name>
+ <supporting-port>C1</supporting-port>
<port-direction>bidirectional</port-direction>
- <supporting-port>C4</supporting-port>
</mapping>
</nodes>
</network>