BUG 5783: Ping test is FAILED from VM to Invisible IP which
is hosted non-nexthop.
a. Ensure that SubnetRoutePacketHandler can
work in deployments where DPNs (i.e., Computes)
are connected to different PLs of an ODL Cluster
(i.e., different ODL instances). More specifically,
this leads to a deployment where the nexthop
reports to one PL but the invisible IP is in a DPN
that is reporting to a different PL in a clustered
environment.
b. Ensure that SubnetRoutePacketHandler can
work with apply_actions rule used in FIB Table
(i.e., Table 22).
c. Create Table 22 (SubnetRoute Table) rules
as default Table Miss Flows instead of dynamically
creating them on the fly in FibManager.
Change-Id: I86e0b3ff8761b054603bc9bb7853340078ad653d
Signed-off-by: Suraj Ranjan <suraj.ranjan@ericsson.com>
Co-Authored-By: Vivekanandan Narasimhan <n.vivekanandan@ericsson.com>