--- /dev/null
+*** Settings ***
+Documentation Test suite for IPv6 flow labelk
+Suite Setup Create Session session http://${CONTROLLER}:${RESTCONFPORT} auth=${AUTH} headers=${HEADERS_XML}
+Suite Teardown Delete All Sessions
+Library SSHLibrary
+Library Collections
+Library OperatingSystem
+Library ../../../libraries/RequestsLibrary.py
+Library ../../../libraries/Common.py
+Variables ../../../variables/Variables.py
+
+*** Variables ***
+${REST_CON} /restconf/config/opendaylight-inventory:nodes
+${REST_OPR} /restconf/operational/opendaylight-inventory:nodes
+${FILE} ${CURDIR}/../../../variables/xmls/f23.xml
+${FLOW} 146
+${TABLE} 2
+@{FLOWELMENTS} metadata=0x3039 tcp6 ipv6 ipv6_dst=fe80:2acf:e9ff:fe21::/94 nw_tos=240 nw_ecn=3 tp_src=183
+... tp_dst=8080 ipv6_src=1234:5678:9abc:def0:fdc0::/76 dec_ttl ipv6_label=0x00021
+
+*** Test Cases ***
+Add a flow - Output to physical port#
+ [Documentation] Push a flow through REST-API
+ [Tags] Push
+ ${body} OperatingSystem.Get File ${FILE}
+ Set Suite Variable ${body}
+ ${resp} Putxml session ${REST_CON}/node/openflow:1/table/${TABLE}/flow/${FLOW} data=${body}
+ Should Be Equal As Strings ${resp.status_code} 200
+
+Verify after adding flow config - Output to physical port#
+ [Documentation] Verify the flow
+ [Tags] Get
+ ${resp} get session ${REST_CON}/node/openflow:1/table/${TABLE}/flow/${FLOW} headers=${ACCEPT_XML}
+ Should Be Equal As Strings ${resp.status_code} 200
+ compare xml ${body} ${resp.content}
+
+Verify flows after adding flow config on OVS
+ [Documentation] Checking Flows on switch
+ [Tags] Switch
+ sleep 1
+ write dpctl dump-flows -O OpenFlow13
+ ${body} OperatingSystem.Get File ${FILE}
+ ${switchouput} Read Until >
+ : FOR ${flowElement} IN @{FLOWELMENTS}
+ \ should Contain ${switchouput} ${flowElement}
+
+Remove a flow - Output to physical port#
+ [Documentation] Remove a flow
+ [Tags] remove
+ ${resp} Delete session ${REST_CON}/node/openflow:1/table/${TABLE}/flow/${FLOW}
+ Should Be Equal As Strings ${resp.status_code} 200
+
+Verify after deleting flow config - Output to physical port#
+ [Documentation] Verify the flow
+ [Tags] Get
+ ${resp} Get session ${REST_CON}/node/openflow:1/table/${TABLE}
+ Should Not Contain ${resp.content} ${FLOW}
+
+Verify flows after deleting flow config on OVS
+ [Documentation] Checking Flows on switch
+ [Tags] Switch
+ Sleep 1
+ write dpctl dump-flows -O OpenFlow13
+ ${body} OperatingSystem.Get File ${FILE}
+ ${switchouput} Read Until >
+ : FOR ${flowElement} IN @{FLOWELMENTS}
+ \ should Not Contain ${switchouput} ${flowElement}