Cleanup ovsdb suites
[integration/test.git] / csit / suites / ovsdb / Southbound_Domain / 030__configure_exit_ovsdb_node.robot
index b36f708b9b65432b9af3bd3fc8aaaf9ae6ec06df..5c9e91e4a6bceba0f6449dbeb093205f201eb8c1 100644 (file)
 *** Settings ***
 Documentation     Test suite for Connection Manager
-Suite Setup       Configure Exit OVSDB Node Suite Setup
-Suite Teardown    Configure Exit OVSDB Node Suite Teardown
+Suite Setup       OVSDB.Suite Setup
+Suite Teardown    Suite Teardown
 Test Setup        SetupUtils.Setup_Test_With_Logging_And_Without_Fast_Failing
 Force Tags        Southbound
-Library           OperatingSystem
-Library           String
 Library           RequestsLibrary
+Resource          ../../../libraries/OVSDB.robot
 Resource          ../../../libraries/SetupUtils.robot
 Resource          ../../../libraries/Utils.robot
-Resource          ../../../libraries/OVSDB.robot
-Variables         ../../../variables/Variables.py
+Resource          ../../../variables/Variables.robot
 
 *** Variables ***
-${OVSDB_PORT}     6634
-${BRIDGE}         ovsdb-csit-test-bridge
-${SOUTHBOUND_CONFIG_API}    ${CONFIG_TOPO_API}/topology/ovsdb:1/node/ovsdb:%2F%2F${TOOLS_SYSTEM_IP}:${OVSDB_PORT}
-${OVSDB_CONFIG_DIR}    ${CURDIR}/../../../variables/ovsdb
-@{node_list}      ${BRIDGE}    vx1
+${BRIDGE}         ovsconf_exit_br
+${PORT1}          vx1
+${PORT2}          vx2
+@{NODE_LIST}      ${BRIDGE}    ${PORT1}
 
 *** Test Cases ***
 Create a Topology in OVSDB node
     [Documentation]    Create topology in OVSDB and ready it for further tests
-    Run Command On Remote System    ${TOOLS_SYSTEM_IP}    sudo ovs-vsctl del-manager
-    Run Command On Remote System    ${TOOLS_SYSTEM_IP}    sudo ovs-vsctl add-br ${BRIDGE}
-    Run Command On Remote System    ${TOOLS_SYSTEM_IP}    sudo ovs-vsctl add-port ${BRIDGE} vx1 -- set Interface vx1 type=vxlan options:remote_ip=192.168.1.11
-    Run Command On Remote System    ${TOOLS_SYSTEM_IP}    sudo ovs-vsctl set-manager ptcp:6634
+    Utils.Run Command On Remote System    ${TOOLS_SYSTEM_IP}    sudo ovs-vsctl del-manager
+    Utils.Run Command On Remote System    ${TOOLS_SYSTEM_IP}    sudo ovs-vsctl add-br ${BRIDGE}
+    Utils.Run Command On Remote System    ${TOOLS_SYSTEM_IP}    sudo ovs-vsctl add-port ${BRIDGE} ${PORT1} -- set Interface ${PORT1} type=vxlan options:remote_ip=192.168.1.11
+    Utils.Run Command On Remote System    ${TOOLS_SYSTEM_IP}    sudo ovs-vsctl set-manager ptcp:6634
 
 Connect to OVSDB Node
     [Documentation]    Initiate the connection to OVSDB node from controller
-    ${sample}    OperatingSystem.Get File    ${OVSDB_CONFIG_DIR}/connect.json
-    ${sample1}    Replace String    ${sample}    127.0.0.1    ${TOOLS_SYSTEM_IP}
-    ${body}    Replace String    ${sample1}    61644    ${OVSDB_PORT}
-    Log    URL is ${SOUTHBOUND_CONFIG_API}
-    ${resp}    RequestsLibrary.Put Request    session    ${SOUTHBOUND_CONFIG_API}    data=${body}
-    Log    ${resp.content}
-    Should Contain    ${ALLOWED_STATUS_CODES}    ${resp.status_code}
+    OVSDB.Connect To Ovsdb Node    ${TOOLS_SYSTEM_IP}
 
 Get Operational Topology
     [Documentation]    This request will fetch the operational topology from the connected OVSDB nodes
-    Wait Until Keyword Succeeds    8s    2s    Check For Elements At URI    ${OPERATIONAL_TOPO_API}    ${node_list}
-    [Teardown]    Report_Failure_Due_To_Bug    5221
+    BuiltIn.Wait Until Keyword Succeeds    8s    2s    Utils.Check For Elements At URI    ${OPERATIONAL_TOPO_API}    ${NODE_LIST}    pretty_print_json=True
+    [Teardown]    Utils.Report_Failure_Due_To_Bug    5221
 
 Verify Bridge Port Not In Config DS
     [Documentation]    This will fetch the configuration topology from configuration data store to verify the bridge is added to the data store
-    @{list}    Create List    vx1
-    Wait Until Keyword Succeeds    8s    2s    Check For Elements Not At URI    ${CONFIG_TOPO_API}    ${list}
+    @{list} =    BuiltIn.Create List    ${PORT1}
+    BuiltIn.Wait Until Keyword Succeeds    8s    2s    Utils.Check For Elements Not At URI    ${CONFIG_TOPO_API}    ${list}    pretty_print_json=True
 
 Create bridge of already added bridge
     [Documentation]    This will add bridge to the config datastore
-    ${sample}    OperatingSystem.Get File    ${OVSDB_CONFIG_DIR}/create_bridge.json
-    ${sample1}    Replace String    ${sample}    tcp:127.0.0.1:6633    tcp:${ODL_SYSTEM_IP}:6633
-    ${sample2}    Replace String    ${sample1}    127.0.0.1    ${TOOLS_SYSTEM_IP}
-    ${sample3}    Replace String    ${sample2}    br01    ${BRIDGE}
-    ${body}    Replace String    ${sample3}    61644    ${OVSDB_PORT}
-    Log    URL is ${SOUTHBOUND_CONFIG_API}%2Fbridge%2F${BRIDGE}
-    Log    data: ${body}
-    ${resp}    RequestsLibrary.Put Request    session    ${SOUTHBOUND_CONFIG_API}%2Fbridge%2F${BRIDGE}    data=${body}
-    Log    ${resp.content}
-    Should Contain    ${ALLOWED_STATUS_CODES}    ${resp.status_code}
+    OVSDB.Add Bridge To Ovsdb Node    ${TOOLS_SYSTEM_IP}:${OVSDB_NODE_PORT}    ${TOOLS_SYSTEM_IP}    ${BRIDGE}    0000000000000030
 
 Get Config Topology with Bridge
     [Documentation]    This will fetch the configuration topology from configuration data store to verify the bridge is added to the data store
-    @{list}    Create List    ${BRIDGE}
-    Wait Until Keyword Succeeds    8s    2s    Check For Elements At URI    ${CONFIG_TOPO_API}    ${list}
+    @{list} =    BuiltIn.Create List    ${BRIDGE}
+    BuiltIn.Wait Until Keyword Succeeds    8s    2s    Utils.Check For Elements At URI    ${CONFIG_TOPO_API}    ${list}    pretty_print_json=True
 
 Create Port of already added port in OVSDB
     [Documentation]    This will add port/interface to the config datastore
-    ${sample}    OperatingSystem.Get File    ${OVSDB_CONFIG_DIR}/create_port.json
-    ${sample1}    Replace String    ${sample}    vxlanport    vx1
-    ${body}    Replace String    ${sample1}    192.168.0.21    192.168.1.10
-    Log    URL is ${SOUTHBOUND_CONFIG_API}%2Fbridge%2F${BRIDGE}/termination-point/vx1/
-    Log    data: ${body}
-    ${resp}    RequestsLibrary.Put Request    session    ${SOUTHBOUND_CONFIG_API}%2Fbridge%2F${BRIDGE}/termination-point/vx1/    data=${body}
-    Log    ${resp.content}
-    Should Contain    ${ALLOWED_STATUS_CODES}    ${resp.status_code}
+    OVSDB.Add Termination Point    ${TOOLS_SYSTEM_IP}:${OVSDB_NODE_PORT}    ${BRIDGE}    ${PORT1}    10.0.0.10
 
 Get Config Topology with Bridge and Port
     [Documentation]    This will fetch the configuration topology from configuration data store to verify the bridge is added to the data store
-    Wait Until Keyword Succeeds    8s    2s    Check For Elements At URI    ${CONFIG_TOPO_API}    ${node_list}
+    BuiltIn.Wait Until Keyword Succeeds    8s    2s    Utils.Check For Elements At URI    ${CONFIG_TOPO_API}    ${NODE_LIST}    pretty_print_json=True
 
 Modify the destination IP of Port
     [Documentation]    This will modify the dst ip of existing port
-    ${sample}    OperatingSystem.Get File    ${OVSDB_CONFIG_DIR}/create_port.json
-    ${sample1}    Replace String    ${sample}    vxlanport    vx1
-    ${body}    Replace String    ${sample1}    192.168.0.21    10.0.0.19
-    Log    URL is ${SOUTHBOUND_CONFIG_API}%2Fbridge%2F${BRIDGE}/termination-point/vx1/
-    Log    data: ${body}
-    ${resp}    RequestsLibrary.Put Request    session    ${SOUTHBOUND_CONFIG_API}%2Fbridge%2F${BRIDGE}/termination-point/vx1/    data=${body}
-    Log    ${resp.content}
-    Should Be Equal As Strings    ${resp.status_code}    200
+    OVSDB.Add Termination Point    ${TOOLS_SYSTEM_IP}:${OVSDB_NODE_PORT}    ${BRIDGE}    ${PORT1}    10.0.0.19
 
 Get Operational Topology with modified Port
     [Documentation]    This request will fetch the operational topology after the Port is added to the bridge
-    @{list}    Create List    ${BRIDGE}    vx1    10.0.0.19
-    Wait Until Keyword Succeeds    8s    2s    Check For Elements At URI    ${OPERATIONAL_TOPO_API}    ${list}
-    [Teardown]    Report_Failure_Due_To_Bug    5221
+    @{list} =    BuiltIn.Create List    ${BRIDGE}    ${PORT1}    10.0.0.19
+    BuiltIn.Wait Until Keyword Succeeds    8s    2s    Utils.Check For Elements At URI    ${OPERATIONAL_TOPO_API}    ${list}    pretty_print_json=True
+    [Teardown]    Utils.Report_Failure_Due_To_Bug    5221
 
 Create Port and attach to a Bridge
     [Documentation]    This request will creates port/interface and attach it to the specific bridge
-    ${body}    OperatingSystem.Get File    ${OVSDB_CONFIG_DIR}/create_port.json
-    Log    URL is ${SOUTHBOUND_CONFIG_API}%2Fbridge%2F${BRIDGE}/termination-point/vxlanport/
-    Log    data: ${body}
-    ${resp}    RequestsLibrary.Put Request    session    ${SOUTHBOUND_CONFIG_API}%2Fbridge%2F${BRIDGE}/termination-point/vxlanport/    data=${body}
-    Log    ${resp.content}
-    Should Contain    ${ALLOWED_STATUS_CODES}    ${resp.status_code}
+    OVSDB.Add Termination Point    ${TOOLS_SYSTEM_IP}:${OVSDB_NODE_PORT}    ${BRIDGE}    ${PORT2}    10.0.0.121
 
 Get Operational Topology with Port
     [Documentation]    This request will fetch the operational topology after the Port is added to the bridge
-    @{list}    Create List    ${BRIDGE}    vxlanport
-    Wait Until Keyword Succeeds    8s    2s    Check For Elements At URI    ${OPERATIONAL_TOPO_API}    ${list}
-    [Teardown]    Report_Failure_Due_To_Bug    5221
+    @{list} =    BuiltIn.Create List    ${BRIDGE}    ${PORT2}
+    BuiltIn.Wait Until Keyword Succeeds    8s    2s    Utils.Check For Elements At URI    ${OPERATIONAL_TOPO_API}    ${list}    pretty_print_json=True
+    [Teardown]    Utils.Report_Failure_Due_To_Bug    5221
 
 Delete the Port1
     [Documentation]    This request will delete the port node from the bridge node and data store.
-    ${resp}    RequestsLibrary.Delete Request    session    ${SOUTHBOUND_CONFIG_API}%2Fbridge%2F${BRIDGE}/termination-point/vx1/
-    Should Be Equal As Strings    ${resp.status_code}    200    Response    status code error
+    ${resp} =    RequestsLibrary.Delete Request    session    ${SOUTHBOUND_NODE_CONFIG_API}%2Fbridge%2F${BRIDGE}/termination-point/${PORT1}/
+    BuiltIn.Should Be Equal As Strings    ${resp.status_code}    200
 
 Get Operational Topology after deletion of Port1
     [Documentation]    This request will fetch the operational topology after the Port is added to the bridge
-    @{list}    Create List    vx1
-    Wait Until Keyword Succeeds    8s    2s    Check For Elements Not At URI    ${OPERATIONAL_TOPO_API}    ${list}
+    @{list} =    BuiltIn.Create List    ${PORT1}
+    BuiltIn.Wait Until Keyword Succeeds    8s    2s    Utils.Check For Elements Not At URI    ${OPERATIONAL_TOPO_API}    ${list}    pretty_print_json=True
 
 Delete the Port2
     [Documentation]    This request will delete the port node from the bridge node and data store.
-    ${resp}    RequestsLibrary.Delete Request    session    ${SOUTHBOUND_CONFIG_API}%2Fbridge%2F${BRIDGE}/termination-point/vxlanport/
-    Should Be Equal As Strings    ${resp.status_code}    200    Response    status code error
+    ${resp} =    RequestsLibrary.Delete Request    session    ${SOUTHBOUND_NODE_CONFIG_API}%2Fbridge%2F${BRIDGE}/termination-point/${PORT2}/
+    BuiltIn.Should Be Equal As Strings    ${resp.status_code}    200
 
 Get Operational Topology after Deletion of Port2
     [Documentation]    This request will fetch the operational topology after the Port is deleted
-    @{list}    Create List    vxlanport
-    Wait Until Keyword Succeeds    8s    2s    Check For Elements Not At URI    ${OPERATIONAL_TOPO_API}    ${list}
+    @{list} =    BuiltIn.Create List    ${PORT2}
+    BuiltIn.Wait Until Keyword Succeeds    8s    2s    Utils.Check For Elements Not At URI    ${OPERATIONAL_TOPO_API}    ${list}    pretty_print_json=True
 
 Delete the Bridge
     [Documentation]    This request will delete the bridge node from the config data store.
-    ${resp}    RequestsLibrary.Delete Request    session    ${SOUTHBOUND_CONFIG_API}%2Fbridge%2F${BRIDGE}
-    Should Be Equal As Strings    ${resp.status_code}    200    Response    status code error
+    ${resp} =    RequestsLibrary.Delete Request    session    ${SOUTHBOUND_NODE_CONFIG_API}%2Fbridge%2F${BRIDGE}
+    BuiltIn.Should Be Equal As Strings    ${resp.status_code}    200
 
 Get Operational Topology after Deletion of Bridge
     [Documentation]    This request will fetch the operational topology after the Bridge is deleted
-    @{list}    Create List    ${BRIDGE}    vxlanport    vx1
-    Wait Until Keyword Succeeds    8s    2s    Check For Elements Not At URI    ${OPERATIONAL_TOPO_API}    ${list}
+    @{list} =    BuiltIn.Create List    ${BRIDGE}    ${PORT1}    ${PORT2}
+    BuiltIn.Wait Until Keyword Succeeds    8s    2s    Utils.Check For Elements Not At URI    ${OPERATIONAL_TOPO_API}    ${list}    pretty_print_json=True
 
 Delete the OVSDB Node
     [Documentation]    This request will delete the OVSDB node
-    ${resp}    RequestsLibrary.Delete Request    session    ${SOUTHBOUND_CONFIG_API}
-    Should Be Equal As Strings    ${resp.status_code}    200    Response    status code error
+    ${resp} =    RequestsLibrary.Delete Request    session    ${SOUTHBOUND_NODE_CONFIG_API}
+    BuiltIn.Should Be Equal As Strings    ${resp.status_code}    200
 
 Get Operational Topology after Deletion of OVSDB Node
     [Documentation]    This request will fetch the operational topology after the OVSDB node is deleted
-    @{list}    Create List    ovsdb://${TOOLS_SYSTEM_IP}:${OVSDB_PORT}    ${BRIDGE}    vxlanport    vx1
-    Wait Until Keyword Succeeds    8s    2s    Check For Elements Not At URI    ${OPERATIONAL_TOPO_API}    ${list}
+    @{list} =    BuiltIn.Create List    ovsdb://${TOOLS_SYSTEM_IP}:${OVSDB_NODE_PORT}    ${BRIDGE}    ${PORT1}    ${PORT2}
+    BuiltIn.Wait Until Keyword Succeeds    8s    2s    Utils.Check For Elements Not At URI    ${OPERATIONAL_TOPO_API}    ${list}    pretty_print_json=True
 
 Check For Bug 4756
     [Documentation]    bug 4756 has been seen in the OVSDB Southbound suites. This test case should be one of the last test
     ...    case executed
-    Check Karaf Log File Does Not Have Messages    ${ODL_SYSTEM_IP}    SimpleShardDataTreeCohort.*Unexpected failure in validation phase
-    [Teardown]    Report_Failure_Due_To_Bug    4756
+    Utils.Check Karaf Log File Does Not Have Messages    ${ODL_SYSTEM_IP}    SimpleShardDataTreeCohort.*Unexpected failure in validation phase
+    [Teardown]    Utils.Report_Failure_Due_To_Bug    4756
 
 Check For Bug 4794
     [Documentation]    bug 4794 has been seen in the OVSDB Southbound suites. This test case should be one of the last test
     ...    case executed.
-    Check Karaf Log File Does Not Have Messages    ${ODL_SYSTEM_IP}    Shard.*shard-topology-operational An exception occurred while preCommitting transaction
-    [Teardown]    Report_Failure_Due_To_Bug    4794
+    Utils.Check Karaf Log File Does Not Have Messages    ${ODL_SYSTEM_IP}    Shard.*shard-topology-operational An exception occurred while preCommitting transaction
+    [Teardown]    Utils.Report_Failure_Due_To_Bug    4794
 
 *** Keywords ***
-Configure Exit OVSDB Node Suite Setup
-    SetupUtils.Setup_Utils_For_Setup_And_Teardown
-    Create Session    session    http://${ODL_SYSTEM_IP}:${RESTCONFPORT}    auth=${AUTH}    headers=${HEADERS}
-
-Configure Exit OVSDB Node Suite Teardown
+Suite Teardown
     [Documentation]    Cleans up test environment, close existing sessions.
-    Clean OVSDB Test Environment    ${TOOLS_SYSTEM_IP}
-    RequestsLibrary.Delete Request    session    ${CONFIG_TOPO_API}/topology/ovsdb:1/node/ovsdb:%2F%2F${TOOLS_SYSTEM_IP}:${OVSDB_PORT}
-    ${resp}    RequestsLibrary.Get Request    session    ${CONFIG_TOPO_API}
-    Log    ${resp.content}
-    Delete All Sessions
+    @{uris} =    Builtin.Create List    ${SOUTHBOUND_NODE_CONFIG_API}
+    OVSDB.Suite Teardown    ${uris}