fix ServiceHandler SpotBugs false positives
[transportpce.git] / tests / honeynode / 2.2.1 / honeynode-plugin-impl / src / main / resources / honeycomb-minimal-resources / config / yang / openconfig / openconfig-alarm-types@2018-01-16.yang
1 module openconfig-alarm-types {
2
3   yang-version "1";
4
5   // namespace
6   namespace "http://openconfig.net/yang/alarms/types";
7
8   prefix "oc-alarm-types";
9
10   // import some basic types
11   import openconfig-extensions { prefix oc-ext; }
12
13   // meta
14   organization "OpenConfig working group";
15
16   contact
17     "OpenConfig working group
18     www.openconfig.net";
19
20   description
21     "This module defines operational state data related to alarms
22     that the device is reporting.
23
24     This model reuses some data items defined in the draft IETF
25     YANG Alarm Module:
26     https://tools.ietf.org/html/draft-vallin-netmod-alarm-module-02
27
28     Portions of this code were derived from the draft IETF YANG Alarm
29     Module. Please reproduce this note if possible.
30
31     IETF code is subject to the following copyright and license:
32     Copyright (c) IETF Trust and the persons identified as authors of
33     the code.
34     All rights reserved.
35
36     Redistribution and use in source and binary forms, with or without
37     modification, is permitted pursuant to, and subject to the license
38     terms contained in, the Simplified BSD License set forth in
39     Section 4.c of the IETF Trust's Legal Provisions Relating
40     to IETF Documents (http://trustee.ietf.org/license-info).";
41
42   oc-ext:openconfig-version "0.2.0";
43
44   revision "2018-01-16" {
45     description
46       "Moved alarm identities into separate types module";
47     reference "0.2.0";
48   }
49
50   // identity statements
51   identity OPENCONFIG_ALARM_TYPE_ID {
52     description
53       "Base identity for alarm type ID profiles";
54   }
55
56   identity AIS {
57     base OPENCONFIG_ALARM_TYPE_ID;
58     description
59       "Defines an alarm indication signal type of alarm";
60   }
61
62   identity EQPT {
63     base OPENCONFIG_ALARM_TYPE_ID;
64     description
65       "Defines an equipment related type of alarm that is specific
66        to the physical hardware";
67   }
68
69   identity LOS {
70     base OPENCONFIG_ALARM_TYPE_ID;
71     description
72       "Defines a loss of signal type of alarm";
73   }
74
75   identity OTS {
76     base OPENCONFIG_ALARM_TYPE_ID;
77     description
78       "Defines a optical transport signal type of alarm";
79   }
80
81   identity OPENCONFIG_ALARM_SEVERITY {
82     description
83       "Base identity for alarm severity profiles. Derived
84       identities are based on contents of the draft
85       IETF YANG Alarm Module";
86     reference
87       "IETF YANG Alarm Module: Draft - typedef severity
88       https://tools.ietf.org/html/draft-vallin-netmod-alarm-module-02";
89
90   }
91
92   identity UNKNOWN {
93     base OPENCONFIG_ALARM_SEVERITY;
94     description
95       "Indicates that the severity level could not be determined.
96       This level SHOULD be avoided.";
97   }
98
99   identity MINOR {
100     base OPENCONFIG_ALARM_SEVERITY;
101     description
102       "Indicates the existence of a non-service affecting fault
103       condition and that corrective action should be taken in
104       order to prevent a more serious (for example, service
105       affecting) fault. Such a severity can be reported, for
106       example, when the detected alarm condition is not currently
107       degrading the capacity of the resource";
108   }
109
110   identity WARNING {
111     base OPENCONFIG_ALARM_SEVERITY;
112     description
113       "Indicates the detection of a potential or impending service
114       affecting fault, before any significant effects have been felt.
115       Action should be taken to further diagnose (if necessary) and
116       correct the problem in order to prevent it from becoming a more
117       serious service affecting fault.";
118   }
119
120   identity MAJOR {
121     base OPENCONFIG_ALARM_SEVERITY;
122     description
123       "Indicates that a service affecting condition has developed
124       and an urgent corrective action is required. Such a severity
125       can be reported, for example, when there is a severe
126       degradation in the capability of the resource and its full
127       capability must be restored.";
128   }
129
130   identity CRITICAL {
131     base OPENCONFIG_ALARM_SEVERITY;
132     description
133       "Indicates that a service affecting condition has occurred
134       and an immediate corrective action is required. Such a
135       severity can be reported, for example, when a resource becomes
136       totally out of service and its capability must be restored.";
137   }