... TODO: Change the 4 testcases to use unique message IDs.
Suite Setup Setup_Everything
Suite Teardown Teardown_Everything
-Test Setup SetupUtils.Setup_Test_With_Logging_And_Fast_Failing
-Test Teardown FailFast.Start_Failing_Fast_If_This_Failed
+Test Setup SetupUtils.Setup_Test_With_Logging_And_Without_Fast_Failing
Library RequestsLibrary
Library SSHLibrary
Resource ${CURDIR}/../../../libraries/FailFast.robot
*** Test Cases ***
Connect_To_ODL_Netconf
[Documentation] Connect to ODL Netconf and fail if that is not possible.
+ Create_ODL_Netconf_Connection
Open_ODL_Netconf_Connection
- ${hello_message}= Get_Data hello
- Transmit_Message ${hello_message}
Get_Config_Running
[Documentation] Make sure the configuration has only the default elements in it.
- ${reply}= Load_And_Send_Message get-config
- BuiltIn.Should_Not_Contain ${reply} <name>name0</name>
- BuiltIn.Should_Not_Contain ${reply} <name>name1</name>
- BuiltIn.Should_Not_Contain ${reply} <name>name2</name>
- BuiltIn.Should_Not_Contain ${reply} <name>name3</name>
- BuiltIn.Should_Not_Contain ${reply} <name>name4</name>
- BuiltIn.Set_Suite_Variable ${empty_config} ${reply}
+ Check_Test_Objects_Not_Present_In_Config get-config
Missing_Message_ID_Attribute
[Documentation] Check that messages with missing "message-ID" attribute are rejected with the correct error (RFC 6241, section 4.1).
Get_Config_Running_To_Confirm_No_Edit_Before_Commit
[Documentation] Make sure the running configuration is still unchanged as the change was not commited yet.
- Send_And_Check get-config-no-edit-before-commit ${empty_config}
+ Check_Test_Objects_Not_Present_In_Config get-config-no-edit-before-commit
Commit_Edit
[Documentation] Commit the change and check the reply.
${data}= Utils.Get_Data_From_URI config config:modules headers=${ACCEPT_XML}
BuiltIn.Should_Contain ${data} <name>name0</name>
+Terminate_Connection_Gracefully
+ [Documentation] Close the session and disconnect.
+ Close_ODL_Netconf_Connection_Gracefully
+
+name0_In_Config_Modules_Via_Restconf_After_Disconnect
+ [Documentation] Check that the change is still visible through Restconf after Netconf disconnect.
+ ${data}= Utils.Get_Data_From_URI config config:modules headers=${ACCEPT_XML}
+ BuiltIn.Should_Contain ${data} <name>name0</name>
+
+Reconnect_To_ODL_Netconf_After_Graceful_Session_End
+ [Documentation] Reconnect to ODL Netconf and fail if that is not possible.
+ Open_ODL_Netconf_Connection
+
+name0_In_Config_Running_After_Reconnect
+ [Documentation] Check that the change is now in the configuration.
+ ${reply}= Load_And_Send_Message get-config-edit-after-commit
+ BuiltIn.Should_Contain ${reply} <name>name0</name>
+
+name0_In_Config_Modules_Via_Restconf_After_Reconnect
+ [Documentation] Check that the change is still visible through Restconf after Netconf reconnect.
+ ${data}= Utils.Get_Data_From_URI config config:modules headers=${ACCEPT_XML}
+ BuiltIn.Should_Contain ${data} <name>name0</name>
+
Edit_Config_Modules_Create_Shall_Fail_Now
[Documentation] Request a "create" operation of an element that already exists and check that it fails with the correct error (RFC 6241, section 7.2, operation "create").
Perform_Test config-modules-create
Get_Config_Running_To_Confirm_Delete_After_Commit
[Documentation] Check that the element is gone.
- Send_And_Check get-config-delete-after-commit ${empty_config}
+ Check_Test_Objects_Not_Present_In_Config get-config-delete-after-commit
Restconf_Get_Modules_Shall_Return_404
[Documentation] Check that "Not Found" is returned when Restconf is asked for the deleted element.
${response}= RequestsLibrary.Get config config:modules ${ACCEPT_XML}
- BuiltIn.Should_Be_Equal_As_Strings ${response.status_code} 404
+ BuiltIn.Should_Be_Equal_As_Strings 404 ${response.status_code}
Commit_No_Transaction
- [Documentation] Attempt to perform "commit" when there are no changes in the candidate configuration and check that it fails with the correct error.
- Test_Commit_With_No_Transactions
+ [Documentation] Attempt to perform "commit" when there are no changes in the candidate configuration and check that it returns OK status.
+ Perform_Test commit-no-transaction
-Edit_Config_Another_Modules_Merge
- [Documentation] Create the element in the candidate configuration again and check the reply.
+Edit_Config_Another_Modules_Merge_For_Discard
+ [Documentation] Create an element to be discarded and check the reply.
Perform_Test config-modules-merge-2
-Get_Config_Candidate
- [Documentation] Check that the element is present in the candidate configuration.
+Get_And_Check_Config_Candidate_For_Discard
+ [Documentation] Check that the element to be discarded is present in the candidate configuration.
${reply}= Load_And_Send_Message get-config-candidate
BuiltIn.Should_Contain ${reply} <name>name1</name>
BuiltIn.Should_Not_Contain ${reply} name0
-Discard_Changes
+Discard_Changes_Using_Discard_Request
[Documentation] Ask the server to discard the candidate and check the reply.
Perform_Test commit-discard
-Get_Config_Candidate_To_Confirm_Discard
+Get_And_Check_Config_Candidate_To_Confirm_Discard
[Documentation] Check that the element was really discarded.
- Send_And_Check get-config-candidate-discard ${empty_config}
+ Check_Test_Objects_Not_Present_In_Config get-config-candidate-discard
Edit_Config_Modules_Multiple_Modules_Merge_1
[Documentation] Create the element with "name2" subelement again and check the reply.
BuiltIn.Should_Contain ${data} <name>name3</name>
BuiltIn.Should_Contain ${data} <name>name4</name>
+Abort_Connection_To_Simulate_Session_Failure
+ [Documentation] Simulate session failure by disconnecting without terminating the session.
+ Abort_ODL_Netconf_Connection
+
+name2_name3_name4_In_Config_Modules_Via_Restconf_After_Session_Fail
+ [Documentation] Check that the 3 subelements are visible via Restconf.
+ ${data}= Utils.Get_Data_From_URI config config:modules headers=${ACCEPT_XML}
+ BuiltIn.Should_Contain ${data} <name>name2</name>
+ BuiltIn.Should_Contain ${data} <name>name3</name>
+ BuiltIn.Should_Contain ${data} <name>name4</name>
+
+Reconnect_To_ODL_Netconf_After_Session_Failure
+ [Documentation] Reconnect to ODL Netconf and fail if that is not possible.
+ Open_ODL_Netconf_Connection
+
+name2_name3_name4_In_Running_Config_After_Session_Failure
+ [Documentation] Check that the 3 subelements are now present in the running configuration.
+ ${reply}= Load_And_Send_Message merge-multiple-check
+ BuiltIn.Should_Contain ${reply} <name>name2</name>
+ BuiltIn.Should_Contain ${reply} <name>name3</name>
+ BuiltIn.Should_Contain ${reply} <name>name4</name>
+
Edit_Multiple_Modules_Merge
[Documentation] Add another subelement named "test" to the element and check the reply.
Perform_Test merge-multiple-edit
Commit_Delete_Not_Existing_Module
[Documentation] Attempt to commit and check the reply.
- Test_Commit_With_No_Transactions
- [Teardown] Utils.Report_Failure_Due_To_Bug 4455
+ Perform_Test commit-no-transaction
Remove_Not_Existing_Module
[Documentation] Attempt to remove the "module" element again and check that the operation is "silently ignored".
${data}= OperatingSystem.Get_File ${datadir}${/}${name}.${dataext}
[Return] ${data}
-Open_ODL_Netconf_Connection
+Create_ODL_Netconf_Connection
[Arguments] ${host}=${CONTROLLER} ${port}=${ODL_NETCONF_PORT} ${user}=${ODL_NETCONF_USER} ${password}=${ODL_NETCONF_PASSWORD}
[Documentation] Open a netconf connecion to the given machine.
# The "-s netconf" flag (see the "SSHLibrary.Write" line below) is not
# going to need to use this operation (Netconf Performance and Scaling
# comes to my mind now as one of the things tested is the performance
# of the direct netconf connection.
+ # TODO: Make this keyword return a dictionary object with all the
+ # data about the prepared connection neatly packaged. Make all
+ # the other keywords handling the connection accept such an
+ # object and pull the data out of it rather than relying on
+ # global variables. This will allow for tracking more Netconf
+ # connections, increasing utility.
${control}= SSHLibrary.Open_Connection ${host} prompt=${ODL_SYSTEM_PROMPT} timeout=10s
Utils.Flexible_Controller_Login
BuiltIn.Set_Suite_Variable ${ssh_control} ${control}
${netconf}= SSHLibrary.Open_Connection ${host} prompt=${ODL_SYSTEM_PROMPT} timeout=10s
Utils.Flexible_Controller_Login
BuiltIn.Set_Suite_Variable ${ssh_netconf} ${netconf}
- SSHLibrary.Write sshpass -p ${password} ssh -o UserKnownHostsFile=/dev/null -o StrictHostKeyChecking=no ${user}\@127.0.0.1 -p ${port} -s netconf
+ BuiltIn.Set_Suite_Variable ${ssh_port} ${port}
+ BuiltIn.Set_Suite_Variable ${ssh_user} ${user}
+ BuiltIn.Set_Suite_Variable ${ssh_password} ${password}
+
+Reopen_ODL_Netconf_Connection
+ [Documentation] Reopen a closed netconf connection.
+ SSHLibrary.Write sshpass -p ${ssh_password} ssh -o UserKnownHostsFile=/dev/null -o StrictHostKeyChecking=no ${ssh_user}\@127.0.0.1 -p ${ssh_port} -s netconf
${hello}= SSHLibrary.Read_Until ${ODL_NETCONF_PROMPT}
SSHLibrary.Switch_Connection ${ssh_control}
- SSHLibrary.Write ps -A | grep sshpass | cut -b 1-6
- ${pid}= SSHKeywords.Read_Command_Response
+ ${pid}= SSHLibrary.Execute_Command ps -A | grep sshpass | cut -b 1-6
BuiltIn.Set_Suite_Variable ${ssh_netconf_pid} ${pid}
SSHLibrary.Switch_Connection ${ssh_netconf}
[Return] ${hello}
+Open_ODL_Netconf_Connection
+ [Documentation] Open a prepared netconf connecion.
+ ${hello}= Reopen_ODL_Netconf_Connection
+ ${hello_message}= Get_Data hello
+ Transmit_Message ${hello_message}
+ [Return] ${hello}
+
Transmit_Message
[Arguments] ${message}
[Documentation] Transmit message to Netconf connection and discard the echo of the message.
${expected}= Prepare_For_Search ${expected_reply}
[Return] ${expected}
-Close_ODL_Netconf_Connection
+Abort_ODL_Netconf_Connection
[Documentation] Correctly close the Netconf connection and make sure it is really dead.
BuiltIn.Return_From_Keyword_If ${ssh_netconf_pid} == -1
${kill_command}= BuiltIn.Set_Variable kill ${ssh_netconf_pid}
SSHLibrary.Switch_Connection ${ssh_netconf}
SSHLibrary.Read_Until_Prompt
+Close_ODL_Netconf_Connection_Gracefully
+ Perform_Test close-session
+ Abort_ODL_Netconf_Connection
+
Setup_Everything
[Documentation] Setup resources and create session for Restconf checking.
SetupUtils.Setup_Utils_For_Setup_And_Teardown
Teardown_Everything
[Documentation] Close the Netconf connection and destroy all sessions in the requests library.
- Close_ODL_Netconf_Connection
+ Abort_ODL_Netconf_Connection
RequestsLibrary.Delete_All_Sessions
+Check_Test_Objects_Not_Present_In_Config
+ [Arguments] ${name}
+ [Documentation] Use dataset with the specified name to get the configuration and check that none of our test objects are there.
+ ${reply}= Load_And_Send_Message ${name}
+ BuiltIn.Should_Not_Contain ${reply} <name>name0</name>
+ BuiltIn.Should_Not_Contain ${reply} <name>name1</name>
+ BuiltIn.Should_Not_Contain ${reply} <name>name2</name>
+ BuiltIn.Should_Not_Contain ${reply} <name>name3</name>
+ BuiltIn.Should_Not_Contain ${reply} <name>name4</name>
+
Perform_Test
[Arguments] ${name}
[Documentation] Load and send the request from the dataset and compare the returned reply to the one stored in the dataset.
${actual}= Load_And_Send_Message ${name}
${expected}= Load_Expected_Reply ${name}
${newline}= BuiltIn.Evaluate "\\r\\n"
- BuiltIn.Should_Be_Equal ${actual} ${newline}${expected}${ODL_NETCONF_PROMPT}
+ BuiltIn.Should_Be_Equal ${newline}${expected}${ODL_NETCONF_PROMPT} ${actual}
[Return] ${actual}
Send_And_Check
[Arguments] ${name} ${expected}
${actual}= Load_And_Send_Message ${name}
- BuiltIn.Should_Be_Equal ${actual} ${expected}
-
-Test_Commit_With_No_Transactions
- [Documentation] Issue a "commit" RPC request and check that it fails with "No current transactions" error.
- ${reply}= Load_And_Send_Message commit-no-transaction
- ${expected}= Load_Expected_Reply commit-no-transaction
- BuiltIn.Should_Contain ${reply} ${expected}
+ BuiltIn.Should_Be_Equal ${expected} ${actual}